Open questions?

 +49 2501 92424 0

Reflex level gauge RG40

40 bar

Application and function

The reflex level gauge is a liquid level indicator without lighting device, which is mainly used on storage tanks und low pressure vessels. Due to the special design of the reflective glass, a direct reading of the level is possible without further auxiliary devices.

This product is in accordance to EU-directive 2014/68/EU. Applied policy acc. to DIN EN 13445 and ASME Boiler and Pressure Vessel Code. Considered regulations AD2000. Furthermore, as a plant component for large water room boilers and water tube boilers, this product meets the requirements of the standards DIN EN 12952-7 and DIN EN 12953-6.

Technical basic equipment

Materials made of heat-resistant pressure vessel steel
Freely selectable valve connection orientation
Reflective sight glass made of borosilicate according to DIN 7081
Vent plug BSP G1/2“
Shut-off valve A120-CS PN40 / DN20 or DN25
Drain valve type AV250

Available (optional) versions

 Stainless steel design
Customised process connections
Vent valve
Other shut-off valves
Other drain valves
Inclined design

Images

Technical data

 

 RG40

   

Pressure stage

PN40 / Class300

Application limits with steam

Max. Operating pressure

32 bar

Max. Temperature

+236 °C

Application limits for media without glass attack at maximum pressure

Max. Operating pressure

40 bar

Max. Temperature

+50 °C

Application limits for media without glass attack at maximum temperature

Max. Operating pressure

28 bar

Max. Temperature

+280 °C

Shut-off valve

A120-CS

Drain valve

AV250