Open questions?

 +49 2501 92424 0

Magnetic level gauge NA7-50

20 bar

Application and function

The magnetic level gauge is an indirect level gauge. The boiler level is transmitted analogously 1:1 to the indicating ledge via the float.
The product corresponds to the EU 2014/68/EU.
Applied standards : complies with DIN EN standards or ASME-Boiler.

Technical basic equipment

  • Fluid side stainless steel (1.4404; SA312 Gr. TP316L)
  • Indicating ledge AL_-G (D-06-D-16311-0)
  • Drain plug
  • Ventilation plug

Available (optional) versions

  • Drain valve AV500 (other drain valve on request)
  • Limit switch type M510-1-60 (D-06-D-16312-0) for signaling
  • Primary element type MRK (D-06-D-16313-0) with integrated R/I-converter, output 4-20 mA
  • Light band indicator for remote level indication